<!-- mobian-agent-page publisher="dailydev" canonical="https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b" -->

---
title: Introducing NV-Reason-CT Open 3D CT VLM for Radiologist...
description: NVIDIA introduced NV-Reason-CT, an open foundation vision-language model purpose-built for full 3D CT scan analysis, extending chain-of-thought reasoning to...
canonical: https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b
twitter:card: summary_large_image
twitter:site: @dailydotdev
og:type: website
og:site_name: daily.dev
og:title: Introducing NV-Reason-CT Open 3D CT VLM for Radiologist Chain-of-Thought Reasoning | daily.dev
og:description: NVIDIA introduced NV-Reason-CT, an open foundation vision-language model purpose-built for full 3D CT scan analysis, extending chain-of-thought reasoning to...
og:url: https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b
og:image: https://api.daily.dev/og/posts/8NQ1tKb8B.png
og:image:alt: Introducing NV-Reason-CT Open 3D CT VLM for Radiologist Chain-of-Thought Reasoning
og:image:width: 1200
og:image:height: 630
og:locale: en
---

> ## Documentation Index
> Fetch the complete documentation index at: https://daily.dev/llms.txt
> Use this file to discover all available pages before exploring further.

# Introducing NV-Reason-CT Open 3D CT VLM for Radiologist Chain-of-Thought Reasoning

**[NVIDIA Developer](https://daily.dev/sources/nvidiadev)** · 12 min read · 0 upvotes · 0 comments

## Summary

NVIDIA introduced NV-Reason-CT, an open foundation vision-language model purpose-built for full 3D CT scan analysis, extending chain-of-thought reasoning to volumetric imaging across chest and abdomen. It combines a dedicated 3D ViT encoder (Primus/Colipri) with a Qwen3.5-4B language model using 3D MRoPE to preserve spatial relationships between CT slices, rather than treating volumes as independent 2D frames. Training used a two-stage pipeline: supervised fine-tuning on ~550,000 structured QA examples with radiologist reasoning annotations, followed by GRPO reinforcement learning with anatomy-aware rewards. On the CT-RATE benchmark, it outperforms prior 3D contrastive models, fused 2D/3D MLLMs, and slice-based frontier models like MedGemma 1.5. NIH radiologists praised its auditable, step-by-step reasoning traces. Checkpoints and training recipes are available on Hugging Face and GitHub for researchers and medical AI companies to build on.

## Full article

daily.dev links to this article rather than hosting it. Read it at the original source: <https://developer.nvidia.com/blog/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning>

## Questions this post answers

### What architecture does NV-Reason-CT use for 3D CT scan analysis?

It combines a Qwen3.5-4B language model with a full 3D vision transformer encoder adapted from Primus, initialized with Colipri weights. CT volumes are resampled to 192³ voxels at 2mm isotropic resolution with non-overlapping 8x8x8 patch tokens, producing 13,824 vision tokens, and all tokens (with 3D grid coordinates) are passed to the LLM using 3D MRoPE to preserve spatial relationships.

_daily.dev surfaces architecture deep dives like this for engineers evaluating domain-specific VLM designs._

### How does NV-Reason-CT perform compared to MedGemma 1.5 on CT scan classification?

On the CT-RATE benchmark (18 labels, fixed uniform threshold), NV-Reason-CT scored 0.614 Macro-F1 and 0.871 Macro-AUROC, while MedGemma 1.5, which processes up to 85 axial slices, scored only 0.303 Macro-F1. NV-Reason-CT also outperformed 3D contrastive models like VoxelFM, Pillar-0, CT-CLIP, and Merlin, marking the first open model competitive at both classification and report generation.

_Track benchmark comparisons like these on daily.dev when weighing which medical imaging model fits a project._

### What training data was used to build NV-Reason-CT's radiologist-style reasoning?

The model trained on roughly 550,000 structured QA examples spanning chest and abdominal regions, drawn from CT-RATE, NIH CT datasets, and CancerVerse, supplemented with synthetic reasoning data distilled from large language models grounded in expert radiologist annotations. A second reinforcement learning stage using Group Relative Policy Optimization (GRPO) with anatomy-aware rewards then refined reasoning accuracy per anatomical region.

_Developers building reasoning-trained models can follow training methodology breakdowns like this on daily.dev._

## Similar posts on daily.dev

- [Synthesize Realistic 3D Medical Images at Scale to Ship Pre‑Trained Models](https://daily.dev/posts/synthesize-realistic-3d-medical-images-at-scale-to-ship-pre-trained-models-d59kocakp) · NVIDIA Developer · 0 upvotes · 0 comments
- [Granite 4.0 3B Vision: Compact Multimodal Intelligence for Enterprise Documents](https://daily.dev/posts/granite-4-0-3b-vision-compact-multimodal-intelligence-for-enterprise-documents-susytp9v3) · Hugging Face · 0 upvotes · 0 comments
- [AlpamayoR1: Large Causal Reasoning Models for Autonomous Driving](https://daily.dev/posts/alpamayor1-large-causal-reasoning-models-for-autonomous-driving-xdvgot0xf) · Towards Data Science · 1 upvotes · 0 comments
- [Unlock Reasoning in Llama 3.1-8B via Full Fine-Tuning on NVIDIA DGX Spark – PyTorch](https://daily.dev/posts/unlock-reasoning-in-llama-3-1-8b-via-full-fine-tuning-on-nvidia-dgx-spark-pytorch-9ojnjecng) · PyTorch · 0 upvotes · 0 comments

---

Tags: [#open-source](https://daily.dev/tags/open-source), [#nvidia](https://daily.dev/tags/nvidia), [#reinforcement-learning](https://daily.dev/tags/reinforcement-learning), [#vlm](https://daily.dev/tags/vlm)

[View this post on daily.dev](https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b)

```json
{"@context":"https://schema.org","@graph":[{"@type":"Organization","@id":"https://daily.dev/#organization","name":"daily.dev","url":"https://daily.dev","logo":{"@type":"ImageObject","url":"https://daily.dev/apple-touch-icon.png","width":180,"height":180},"sameAs":["https://twitter.com/dailydotdev","https://github.com/dailydotdev","https://www.linkedin.com/company/daily-dev-ltd"]},{"@type":"WebSite","@id":"https://daily.dev/#website","url":"https://daily.dev","name":"daily.dev","publisher":{"@id":"https://daily.dev/#organization"},"potentialAction":{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://daily.dev/search?q={search_term_string}"},"query-input":"required name=search_term_string"}}]}
{"@context":"https://schema.org","@type":"TechArticle","headline":"Introducing NV-Reason-CT Open 3D CT VLM for Radiologist Chain-of-Thought Reasoning","url":"https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b","mainEntityOfPage":{"@type":"WebPage","@id":"https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b"},"datePublished":"2026-09-23T22:56:45.061Z","dateModified":"2026-09-23T22:57:09.473Z","description":"NVIDIA introduced NV-Reason-CT, an open foundation vision-language model purpose-built for full 3D CT scan analysis, extending chain-of-thought reasoning to...","image":"https://media.daily.dev/image/upload/f_auto,q_auto/v1/posts/b4cd9bb5b8f0ff56754eeb3af9f87b70?_a=AQAEuop","thumbnailUrl":"https://media.daily.dev/image/upload/f_auto,q_auto/v1/posts/b4cd9bb5b8f0ff56754eeb3af9f87b70?_a=AQAEuop","isAccessibleForFree":true,"articleSection":"NVIDIA Developer","inLanguage":"en","publisher":{"@type":"Organization","name":"daily.dev","url":"https://daily.dev","logo":{"@type":"ImageObject","url":"https://daily.dev/apple-touch-icon.png","width":180,"height":180}},"author":{"@type":"Organization","name":"NVIDIA Developer","logo":"https://media.daily.dev/image/upload/t_logo,f_auto/v1/logos/86e45aab42ba48ce83103d01b1119910","url":"https://daily.dev/sources/nvidiadev"},"commentCount":0,"discussionUrl":"https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b","interactionStatistic":[{"@type":"InteractionCounter","interactionType":{"@type":"LikeAction"},"userInteractionCount":0},{"@type":"InteractionCounter","interactionType":{"@type":"CommentAction"},"userInteractionCount":0}],"keywords":"open-source,nvidia,reinforcement-learning,vlm","timeRequired":"PT12M"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://daily.dev"},{"@type":"ListItem","position":2,"name":"NVIDIA Developer","item":"https://daily.dev/sources/nvidiadev"},{"@type":"ListItem","position":3,"name":"Introducing NV-Reason-CT Open 3D CT VLM for Radiologist Chain-of-Thought Reasoning"}]}
{"@context":"https://schema.org","@type":"FAQPage","@id":"https://daily.dev/posts/introducing-nv-reason-ct-open-3d-ct-vlm-for-radiologist-chain-of-thought-reasoning-8nq1tkb8b#faq","mainEntity":[{"@type":"Question","name":"What architecture does NV-Reason-CT use for 3D CT scan analysis?","acceptedAnswer":{"@type":"Answer","text":"It combines a Qwen3.5-4B language model with a full 3D vision transformer encoder adapted from Primus, initialized with Colipri weights. CT volumes are resampled to 192³ voxels at 2mm isotropic resolution with non-overlapping 8x8x8 patch tokens, producing 13,824 vision tokens, and all tokens (with 3D grid coordinates) are passed to the LLM using 3D MRoPE to preserve spatial relationships. daily.dev surfaces architecture deep dives like this for engineers evaluating domain-specific VLM designs."}},{"@type":"Question","name":"How does NV-Reason-CT perform compared to MedGemma 1.5 on CT scan classification?","acceptedAnswer":{"@type":"Answer","text":"On the CT-RATE benchmark (18 labels, fixed uniform threshold), NV-Reason-CT scored 0.614 Macro-F1 and 0.871 Macro-AUROC, while MedGemma 1.5, which processes up to 85 axial slices, scored only 0.303 Macro-F1. NV-Reason-CT also outperformed 3D contrastive models like VoxelFM, Pillar-0, CT-CLIP, and Merlin, marking the first open model competitive at both classification and report generation. Track benchmark comparisons like these on daily.dev when weighing which medical imaging model fits a project."}},{"@type":"Question","name":"What training data was used to build NV-Reason-CT's radiologist-style reasoning?","acceptedAnswer":{"@type":"Answer","text":"The model trained on roughly 550,000 structured QA examples spanning chest and abdominal regions, drawn from CT-RATE, NIH CT datasets, and CancerVerse, supplemented with synthetic reasoning data distilled from large language models grounded in expert radiologist annotations. A second reinforcement learning stage using Group Relative Policy Optimization (GRPO) with anatomy-aware rewards then refined reasoning accuracy per anatomical region. Developers building reasoning-trained models can follow training methodology breakdowns like this on daily.dev."}}]}
```

